In 2001 portable cleanroom foggers were introduced using LN2 and DI Water for smoke studies. The AP35 is the latest ultrapure cleanroom fogger which includes adjustable airflow control, adjustable fog volume, wireless remote control and 9 effective accessories. Clean room foggers support smoke studies for airflow visualization and characterization of clean rooms, medical rooms, ISO suites, sterile rooms, barrier isolators, glove boxes, airflow hoods and fume hoods. Cleanroom ultrapure fogger, LN2 fogger, cleanroom fogger, portable fogger, DI water fogger and CO2 foggers, are also called smoke machines, and are used in smoke studies and air flow characterization of clean rooms, ISO suites, sterile rooms, fume hoods, bio safety cabinets and medical operating rooms. The portable fogger is available for smoke studies in clean rooms, ISO suites, barrier Isolators, glove boxes and sterile rooms. Please review performance comparison below and click on product links in chart on left. Call Applied Physics, Inc. at (719) 428-4042.

 

Smoke Study, Smoke Test or Airflow Visualization StudyFog PurityFog VolumeFog DensityFog DurationVisual Airflow DistanceLiquids UsedShipping DimensionsOptional AccessoriesPower
CRF2 Portable Cleanroom FoggerPure fog
Low cost Fogger

Polyethylene enclosure
about in fume hoods, airflow hoods, small glove boxes

One 60mm fog output

WATCH CRF2 VIDEO
About about about DI Water, Sterile Water or WFI WaterCRF2 ships in box: 22 x 22 x 18 inches

Includes 3 accessories
22″ Fog Curtain Wand, 10 ft. Remote Control Cable, Rolling Carry Case w/ Foam Insert115 VAC, 60 Hz

220 VAC, 50 Hz
CRF6 Cleanroom Fogger supersedes the CRF4 Cleanroom FoggerCRF6 has a dense, Pure Fog and excellent fog volume

316L, electro-polished, stainless steel enclosure with Carry Handles
about in pharmaceutical clean rooms, sterile rooms, medical rooms, ISO suites, semiconductor clean rooms.

Two 80mm Fog Outlets with 50mm and 80mm hose options

WATCH CRF4 VIDEO
about

Adjustable fog volume and airflow velocity, optional wireless remote control

about at max fog volume; or 90 minutes at lowest fog volumeabout DI Water, Sterile Water or WFI WaterCRF4 ships in box, 30 x 21 x 18 inches

Accessories are in additional boxes or rolling carry cases
1.2 M Fog Wand, Wireless Remote Control, 5Mx80mm Fog Hose, CRF4 Rolling Carry Case, 5Mx50mm Hose + 0.6M Fog Wand, Y Adaptor, Y Adaptor w/ Butterfly valves, LED Fog Contrast Light, Accessory Rolling Carry Case w/ Foam Insert115 VAC, 60 Hz

220 VAC, 50 Hz

100VAC, 50Hz
AP35 Portable Cleanroom Ultrapure FoggerUltrapure fog

High volume fog

316L, electro-polished, stainless steel enclosure on rolling SS frame (trolley)
about in clean rooms, medical rooms, sterile rooms, ISO suites

2 internal water heaters and two 80mm fog outlets

WATCH AP35 VIDEO
about

Adjustable fog volume and airflow velocity, optional wireless remote control
about about LN2 + DI Water, Sterile Water or WFI WaterAP35 ships in crate: 1.2 M x 1 M x 0.8 M

Accessories are in additional boxes or rolling carry cases
1.2 M Fog Wand, Wireless Remote Control, 5Mx80mm Fog Hose, CRF4 Rolling Carry Case, 5Mx50mm Hose + 0.6M Fog Wand, Y Adaptor, Y Adaptor w/ Butterfly valves, LED Fog Contrast Light, Accessory Rolling Carry Case w/ Foam Insert, spare LN2 Dewar w/ SS valve controls115 VAC, 60 Hz

220 VAC, 50 Hz

100VAC, 50Hz
AP100 Portable LN2 FoggerUltrapure fog

Highest fog volume for largest clean rooms, stage fog or theater fog

316L, electro-polished, stainless steel enclosure on rolling SS frame (trolley)
about in large clean rooms, sterile rooms, ISO suites

2 internal water heaters and four 80mm fog outputs
about

Adjustable fog volume and airflow velocity, optional wireless remote control
about about LN2 + DI Water, Sterile Water or WFI WaterAP100 ships in crate: 1.2 M x 1.2 M x 1.2M.

Accessories are in additional boxes or rolling carry cases
1.2 M Fog Wand, Wireless Remote Control, 5Mx80mm Fog Hose, CRF4 Rolling Carry Case, 5Mx50mm Hose + 0.6M Fog Wand, Y Adaptor, Y Adaptor w/ Butterfly valves, LED Fog Contrast Light, Accessory Rolling Carry Case w/ Foam Insert115 VAC, 60 Hz

220 VAC, 50 Hz

100VAC, 50Hz
Ultrapure LN2 Fogger, 2001Ultrapure fog

Medium fog volume
about

1 internal water heater and 1 fog output
about about about LN2 + DI Water, Sterile Water or WFI WaterNot KnownAccessories are additional115 VAC, 60 Hz

220 VAC, 50 Hz

100VAC, 50Hz
CO2 Fogger, (Discontinued Production, replaced by CRF2 above)CO2 Fog; Low Cost foggerstarts at about ~ 0.30 cubic meters / minute decreasing to 0 volume as CO2 evaporates over 8 minutes.

For airflow hoods and fume hoods, glove boxes
starting at ~20 ml / minute, and decreasing to 0 density as CO2 ice consumedabout ~ 8 – 10 minutesabout 4-6 feet visual airflowCO2 Ice and Sterile Water or DI Water or WFI Water
CO2 Fogger ships in 22 x Carry Case, Fog Wand, Ice Maker115 VAC, 60 Hz

220 VAC, 50 Hz
Portable FoggerGlycerin liquid and Water used in some pharmaceutical applications, FDA applications and industrial clean roomsabout 0.10 cubic meter / minute

used in industrial clean rooms to search for leaks and balance
about 1.0 to 1.5 ml fog density / minuteabout 45 minutesabout 10-15 feet visual airflow10% Glycerin liquid and 90% water, (Sterile, deionized or WFI)Portable Fogger ships in box, 20 x 18 x 12 inchesIncludes all accessories including Fog Wand, Carry Case, Power Charger, rechargeable Lithium Ion battery, fog hose extension, bottle and filling toolsRechargeable Battery, 115V/220V Charging in 60 Minutes

In 2001 portable cleanroom fogger was developed to use LN2 and DI water to produce about 1.5 cubic meters of fog per minute to visualize airflow turbulence. The new AP35 LN2 portable ultrapure fogger produces 5 cubic meters ultrapure fog per minute, and adds a rolling trolley, adjustable fog controls and wireless remote control. The AP35 produces the same type of ultrapure fog, but 3X more than the portable foggers designed in 2001. It uses 35 Liters LN2 and 5 Liters of De-ionized water, sterile water or WFI water. The AP35 can visualize airflow turbulence and balance airflow between rooms. Ultrapure fog is generated by heating water to form water vapor, and then mixing the water vapor with a nitrogen vapor forming a 2-3 micron diameter fog vapor. LN2 readily boils at room temperatures, producing high volume of nitrogen vapor. The LN2 fogger in 2001 was a mechanical tool with no adjustable controls, which has not changed much since then. The ultrapure fogger today functions in a similar manner as described above, but allows for adjusting the fog volume and airflow velocity, as well as providing wireless remote control. The AP35 Ultrapure Fogger produces 3.5X more ultrapure fog than previous ln2 foggers used in smoke studies and airflow characterization in clean rooms, ISO suites, medical operating rooms, sterile rooms and medical rooms. Ultrapure LN2 foggers provide the highest purity of fog, the highest volume of fog, the highest fog density; all of which combines to provide the longest visual airflow distance. The AP35 LN2 fogger provides about 5 cubic meters of ultrapure fog per minute for up to 70 minutes with 571 ml per minute fog density, providing 20-30 feet of visual airflow using 1 or 2 fog hose outputs. The fog volume can be adjusted between 2 cubic meters and 5 cubic meters per minute. It is the fog density of a fogger that controls the distance of the visual air flow. The higher the fog density, the more visual fog distance is provided, and our AP35 provides 2 times more fog density than similar LN2 ultrapure foggers. No other ultrapure fog generator is capable of this fog volume, yet the AP35 costs nearly the same as other ultrapure fog generators. Our AP100 LN2 Fogger produces 15.5 cubic meters a minute of ultrapure fog and provides four 5Mx80mm fog hose outputs. If you do not want to use LN2, but want high volume fog, consider the CRF4 Cleanroom Fogger. The CRF4 provides about 1.25 cubic meters of pure fog per minute for 40 minutes with 187 ml per minute fog density, providing 10-15 feet of visual airflow. It provides an adjustable fog volume and airflow velocity, touch pad control and wireless remote control. Alternatively, we provide our CRF2 DI Water Fogger for low cost solutions to provide airflow visualization in fume hoods, Bio-Safety Cabinets and Aseptic Isolators. Our foggers are priced according to fog volume produced. 

Deionized water (DI water), sterile water or water for injection (WFI) is combined with liquid nitrogen in the AP35 Ultrapure Fogger to produce 571 ml per minute of fog density. Applied Physics discusses fog volume, fog duration, fog density visual flow distances as a metric so that you can compare performance of different fog generators. It does not make sense to buy a smoke generator on cost, if you do not know how much fog it produces or the visual airflow distance provided; or whether it is a fog that requires cleanup afterwards such as use of smoke sticks.  Ultrasonic foggers use Deionized water (Distilled water) or WFI (water for injection), a pure pharmaceutical water. DI water foggers are more simple to operate and produce much less fog and fog density than an ultrapure fogger. Our CRF2 Cleanroom Fogger supports airflow visualization and airflow recovery tests as defined by ISO 14644-3, B12. CRF4 Cleanroom Fogger is ideal for airflow visualization in clean rooms, ISO suites, medical operating rooms and sterile rooms. Contact Applied Physics, Inc. at TEL: 1-720-635-3931 or 1-303-999-6837.

AP35 Ultrapure Fogger provides 571ml fog density per minute, the highest fog density available of any fogger used around the world to visualize airflow turbulence, airflow patterns, direction and to locate dead airflow zones. The AP35 Ultrapure LN2 Fogger, CRF4 Cleanoom Fogger and CRF-2 DI Water Fogger support ISO 14644-3, USP 797 Insitu Airflow Analysis, Federal Standards 209E and ISO 1446 for clean rooms; as well as USP 800 for Compound Pharmacy.
 

AP35 Ultrapure Fogger supports USP 797, ISO 14644-3, Annex B.7, Federal Standards 209E and ISO 1446 for airflow visualization.

The AP35 Ultrapure LN2 Fogger is designed with a 316L Stainless Steel body and enclosure and electro-polish finish. It provides 571 ml fog density per minute with an adjustable fog output from 2-5 cubic meters per minute for up to 70 minutes operation with 20 to 30 feet of visible airflow for smoke studies and 3D airflow modeling. Ultrapure Foggers are used in smoke studies of ISO suites, sterile rooms and clean rooms that require higher volumes of fog, high fog density and long visual airflow distances. Also referred to as LN2 foggers and liquid nitrogen foggers, an ultrapure fogger can visualize airflow, turbulence, patterns, direction and to locate dead airflow zones in Class 1 to Class 100,000 clean rooms. Although the base cost of the AP35 is nearly the same as similar LN2 foggers, The AP35 produces much more fog and fog density for 2X more visual airflow distance. 

CRF4 Portable Cleanroom Fogger supports smoke studies in Bio-Safety Cabinets (BSC), Barrier Isolators, ISO Suites, Sterile Rooms.

The CRF4 portable fogger is designed with a 316L Stainless Steel body and enclosure and electro-polish finish. It provides 1.25 cubic meters of pure fog per minute with 187 ml of fog density per minute for about 40 minutes with 10-15 feet of visual airflow distance for use in smoke studies and airflow characterization of small clean rooms, fume hoods and aseptic pharmacy isolators. The CRF4 provides airflow control, fog volume control and water level feedback via a LED display and touch pad control. The fog volume is constant at any of 4 levels of fog volume. Touch pad control is provided and a Remote Wireless Control is optionally available for operation behind a closed wall. CRF4 is ideal to visualize airflow turbulence in clean rooms, ISO suites, medical operating rooms and sterile rooms.

CRF2 DI Water Fogger, supporting ISO 14644-3, Annex B.12 Airflow Recovery Tests using 0.5 micron or 1 micron PSL Spheres

cleanroom foggerCRF2 Cleanroom fogger is primarily used in in smoke studies and air flow characterization of fume hoods; and can also be used in airflow recovery tests using 0.5 micron or 1 micron polystyrene latex spheres.  The CRF2 portable cleanroom fogger provides 9 cubic feet of pure fog per minute for about 50 minutes with 7-8 feet of visual airflow distance. The fog is a constant volume output combined with the PSL Spheres. Using a laser particle counter, you can access how fast the PSL Spheres travel through the airflow and out to the exhaust. LOW COST, DI Water Fogger to visualize clean room airflow providing 9cfm of fog for 50 minutes.

CO2 Fogger

CO2 Foggers provide portability and require no power cords for fog operation in smoke studies to visualize airflow and turbulence in clean rooms, sterile rooms and ISO suites. The CO2 Fogger is a low cost fogger producing a visual fog using CO2 ice and warm water to generate a highly visible airflow with a typical 10 minute operating cycle. CO2 Foggers are typically used in rooms where no power access is provided.

Portable DI Water Fogger 

Type of portable fogger are provided, using a battery to provide power to produce a portable fog. The Portable DI Water Fogger uses deionized water or WFI water.

AP35 Ultrapure Fogger uses liquid nitrogen and Deionized Water, sterile water or WFI water, Water for Injection, to create the highest fog density for ultrapure fog to provide superb video and visualization of airflow patterns, direction, turbulence, dead zones and velocity. The AP35 produces up to 5 cubic meters of ultrapure fog per minute with 571 ml fog density to provide 20-30 feet of visual airflow for up to 70 minutes per cycle. No other ultrapure fogger can provide 571 ml fog density per minute. No other ultrapure fogger can provide an adjustable 2 – 5 cubic meters of ultrapure fog per minute with remote control built into the operation controlled by a wireless remote control key Fob. No other ultrapure fogger can provide 20 to 30 feet visualization of airflow in clean rooms, ISO suites, sterile rooms, clean rooms and medical rooms. No contamination is created and no clean up is required after ultrapure fogging. The AP35 is modular in design providing simple operation and maintenance for smoke studies guided by ISO 14644-3, Annex B.7 Airflow Direction Test and Visualization; USP 797 Insitu Airflow Analysis, and Semi-Standards Clean Room guidelines. With 2X more fog, 2X more fog density, 2X more visual airflow distances, it costs nearly the same as similar nitrogen foggers.

CRF4 Cleanroom Fogger is used in smoke studies using DI Water or WFI (water for injection) water to produce 1.25 cubic meters of fog per minute for about 40 minutes with a fog density of 187 ml per minute to provide 10 – 15 feet of visual airflow distance. The CRF4 has an internal power supply, long power cord, 80mm fog hose, LED display, remote control using a Wireless Remote Control Fob. Operational control includes airflow velocity, fog volume control (by turning on 1, 2 or 3 transducers), and an LED display alerts to the LED display for water level feedback. Fog out put has ‘on demand’ fog control for about 40 minutes. No contamination of any kind is created and no clean up is required. Clean room airflow, turbulence, patterns and balance of airflow in smoke studies of Pharmaceutical ISO suites, sterile rooms and aseptic pharmacy isolators to support clean room guidelines: ISO 14644-3, Annex B.7 Airflow Direction Test and Visualization; USP 797 Insitu Airflow Analysis; and Semi-Standards Clean Room guidelines for airflow visualization and analysis.

CRF2 Cleanroom Fogger is used in smoke studies using DI Water or WFI (water for injection) water to produce 9 cubic feet of fog per minute for about 50 minutes with a fog density of 57 ml per minute to provide 7-8 feet of visual airflow distance. The CRF-2 has a separate power supply, 15 foot power cable, 60mm fog hose, optional remote power control using a separate cable, optional fog curtain wand and optional rolling carry/storage case. Fog output is ‘on demand’ using a toggle switch and maximum fog cycle is about 50 minutes. Water can be refilled in less than 15 seconds and fog operation restarted. No contamination of any kind is created and no clean up is required. Clean room airflow, turbulence, patterns and balance of airflow in smoke studies of Pharmaceutical ISO suites, sterile rooms and barrier isolators to support clean room guidelines: ISO 14644-3, Annex B.7 Airflow Direction Test and Visualization; Annex B.12 Airflow Recovery Test; USP 797 Insitu Airflow Analysis; and Semi-Standards Clean Room guidelines for airflow visualization and analysis.

CO2 Fogger is a smoke machine using DI Water and CO2 Ice to provide a dense fog of about 6cfm for 8-10 minutes to visualize airflow in ISO suites and sterile rooms. A CO2 fogger works well to video smoke studies and describe airflow, patterns and turbulence in Pharmaceutical ISO suites guided by USP 797 Pharmaceutical In-Situ Airflow Analysis. No clean up is required after CO2 fog evaporation.

DI Water Fogger is a portable clean room fogger providing airflow visualization of turbulence and dead spots in clean rooms, sterile rooms and ISO suites. No contamination is created and no clean up afterwards is required. Distilled Water or Water for Injection (WFI) is converted to a pure fog vapor for about 50 minutes at 9cfm fog volume to support guidelines for ISO 14644-3, Annex B.12 Airflow Recovery Test using 0.5 micron PSL or 1 micron PSL spheres.