• AP100 Tool Drawer for small tool storage AP100 LN2 Ultrapure Fogger, provides 4 fog hose outputs for total of 15.5 cubic meters ultrapure fog and 30-40 feet of visual fog.
    Ultrapure-Fogger The AP100 is a high volume, ultra pure fog machine using liquid nitrogen and Deionized Water or WFI water to create about 15.5 cubic meters of fog per minute at a fog density of 1520 ml per minute for larger clean rooms, as well as stages and theaters. It is designed with a 316L stainless steel with an electro-polish finish. The AP100 can quickly produce large volumes of stage fog for theater and 3D theaters. The fog output would be used in large sterile rooms, large ISO suites and large semiconductor clean rooms during a 70 minute operating cycle. The AP100 Ultra Pure Fogger complies with USP 797 and ISO 14644-3, Annex B7 and Federal Standard 209E to visually describe airflow, patterns, direction, balance, dead zones and velocity for 3D airflow modeling  in large ISO suites, large sterile rooms and large clean rooms. No other ultra pure fogger is capable of this fog volume, which due to purity, can also be used for theatrical stage fog. No contamination is created and no clean up of any kind is required after visualizing the airflow. The fog evaporates back to the same air we breathe.
    Request a Fogger Quote
  • Accessory Rolling Case, Polyethylene Foam Lined GPF1-CarrierPartsLayout

    Portable Glycol Fogger

    The Portable Glycol Fogger is used in Industrial clean rooms to visualize airflow leaks and locate turbulence. It is a hand held fogger with battery operation and is used in small industrial areas where airflow leaks need to be found. The portable glycol fogger can also be used airflow hoods. The battery is rechargeable in a typical 1 hour period. Spare batteries are available if there is a need to do longer periods of fogging. The size of the Portable Glycol Fogger fits easily into your hand for movement around the cleanroom area, isolators and fume hoods.

    Request a Fogger Quote

  • cleanroom fogger
    The CRF2 Cleanroom Fogger uses 10 ultrasonic devices to produce 0.26 cubic meters per minute with 57 ml of fog density to provide 7-8 feet of visual airflow in fume hoods, bio-safety cabinets, glove boxes; while the CRF4 Cleanroom Fogger uses 35 ultrasonic devices to produce 1.25 cubic meters fog per minute with 170ml fog density to provide 10-15 feet visual airflow in small cleanrooms, ISO suites and sterile rooms. Fog is used in smoke studies to visualize airflow patterns and turbulence in Pharmaceutical ISO suites, sterile rooms, medical rooms and semiconductor clean rooms; providing compliance to USP 797 Pharmaceutical In-situ Airflow Analysis, Airflow Recovery Tests in ISO 14644-3, Visualization Tests for ISO 14644-3 Annex B7, NSF 49 for Bio-Safety Cabinets and Federal Standards 209E for semiconductor clean rooms.
  • CRF4-YAdaptor cleanroom fogger
    Clean-Room-Fogger-CRF-2.pdf CleanRoom Fogger SOP The CRF2 CleanRoom Fogger is a low cost, ultrasonic fogger using 9 high performance, piezo devices to create 0.26 cubic meters per minute (9 cubic feet per minute) of pure fog with a fog density of 57 ml fog density per minute for a typical 50 minute operation. This provides about 7-8 feet of visual fog for for smoke studies and air flow characterization in small areas such as fume hoods and bio-safety cabinets. The CRF2 is compatible with USP 797 Pharmaceutical In-situ Airflow Analysis; USP 800 Compound Pharmacy airflow tests; Airflow Recovery Tests in ISO 14644-3 Annex B12; Airflow Visualization Tests for ISO 14644-3 Annex B7; NSF 49 for Bio-Safety Cabinets; and Semi-Standards Clean Room Guidelines, Federal Standard 209E.
    Request a Fogger Quote
  • cleanroom fogger
      A DI Water Fogger uses ultrasonic devices to create a pure fog to visualize airflow patterns and turbulence in smoke studies of pharmaceutical ISO suites, Bio-Safety Cabinets, medical rooms and clean rooms; providing compliance with USP 797 Pharmaceutical in-situ airflow analysis and the proposed USP 800 Hazardous Drug Compounding, Airflow Recovery Tests of ISO 14644-3 Annex B12, air flow tests for NSF Standard 49, National Sanitation Foundation; Visualization Tests for ISO 14644-3 Annex B7 and Semiconductor clean rooms, Federal Standard 209E.
  • Fog Curtain Wand
    CO2-Fogger.pdf
    The CO2 Fogger is a smoke generator using DI Water and CO2 Ice for airflow visualization to produce a dense fog of about 6cfm for 6-10 minutes. A CO2 fogger works well to video smoke studies and describe airflow, patterns and turbulence in Pharmaceutical ISO suites guided by USP 797 Pharmaceutical In-Situ Airflow Analysis. CO2 Foggers leave no contamination of any kind and no clean up is required after fog evaporation.
  • Stream Fog
    Cleanroom Fogger, CRF4.PDF The CRF4 Cleanroom Fogger uses 35 ultrasonic piezo devices to generate 1.25 cubic meters of pure fog per minute with 187 ml of fog density per minute to provide 10-15 feet of visible air flow for smoke studies and air flow characterization in clean rooms, sterile rooms, medical operating rooms and ISO suites. The CRF4 fog volume competes with LN2 foggers for fog volume performance. But the CRF4 does not use liquid nitrogen, requiring only DI Water or WFI water to produce this higher volume of fog, adding adjustable fog volume, adjustable airflow, and wireless remote control. The CRF4 operates for about 45 minutes at maximum fog volume or up to 90 minutes at lower fog volumes. The CRF4 supports USP 797 In-situ Airflow Analysis; USP 800 Compound Pharmacy airflow tests; Airflow Recovery Tests guided by ISO 14644-3, Annex B12; Airflow Visualization Tests guided by ISO 14644-3 Annex B7; airflow tests for NSF 49 and Bio-Safety Cabinets; and airflow requirements using Semiconductor Clean Room Guidelines, Federal Standard 209E.
    Request a Fogger Quote
  • Fog Curtain Wand ultrapure fogger
    Cleanroom-Ultrapure-Fogger-AP35.pdf AP35 Utrapure Fogger is designed with a 316L Stainless Steel body and enclosure and electro-polish finish. It uses liquid nitrogen and Deionized Water or WFI water to generate about 5 cubic meters of ultra pure fog per minute with a fog density of 571 ml per minute for smoke studies. LN2 fogger technology was developed in 2001 for smoke studies and air flow characterization in clean rooms. The fog output is adjustable from 2-5 cubic meters per minute. The AP35 complies with Semiconductor clean room guidelines, USP 797 Insitu Airflow Analysis and ISO 14644-3 visual airflow requirements to provide 3D airflow modeling in clean rooms, ISO suites, sterile rooms and medical rooms. The AP35 costs nearly the same as competing ultra pure fog generators, yet provides 3X more fog volume, 2X more fog density and 2X more visual airflow distances than competitive LN2 foggers.
    Request a Fogger Quote